Data taken on 23/06/2022

Measuring the lifetime of Feshbach molecules using an association/dissociation sequence.
Jump fast input calibration 194.97G + V * 2.143 G/V
Field is 210G for merging/unmerging
start of ramp 1.7V = 198.6G, end of ramp 0.8V = 196.7G where we hold before dissociation.
Transfer to our DBR tweezer at 1065.499nm = 281.363 THz
This tweezer is kept on at -0.02V=0.12mW throughout the sequence preceding association to prevent servo issues.
Dissociation ramp takes 1ms and then there is the end of the 2ms association ramp. 
time below FR during association ramp: 2/(1.7-0.8)*(1.09-0.8)=0.6444 ms
time below FR during dissociation ramp: 1/(1.7-0.8)*(1.09-0.8)=0.3222 ms
So 1ms total. Add 1ms to the hold time dexter step when plotting.

changing the power for association and hold:
Measure 2: 0.2V = 1.8mW before SLM = 34.8kW/cm2
Measure 3: 0.1V = 1.0mW before SLM = 19.3kW/cm2
Measure 4: 0.8V = 6.5mW before SLM = 126kW/cm2
Measure 5: 0.5V = 4.1mW before SLM = 79.3kW/cm2