Data from 02.07.2022

Eject Cs from a 938 trap to find the overlap position with 817 tweezer.
1. Rearrange Cs to 166 MHz
2. Sweep Cs in 938 over to 180MHz
3. Ramp down 938 to 0.5V=0.88mW=-0.18mK, ramp up the 817 potential to 4V=6.4mW*0.8=+2.2mK
4. hold for 20ms
5. ramp off 817 potential, ramp 938 back up.
6. Sweep back Cs in 938 to 166 MHz for re-image.

Measure, AWG2 V (MHz)
8,98.3
9,98.2
10,98.1
11,98.4
12,98.0
13,98.5
14,97.9
15,97.8
16,98.6
17,97.7
18,98.7
19,98.8
20,97.6